15 research outputs found

    Using Dome C for Moderate Resolution Imaging Spectroradiometer Calibration Stability and Consistency

    Get PDF
    Currently, there are two nearly identical moderate resolution imaging spectroradiometer (MODIS) instruments operated in space: one on the Terra spacecraft launched in December 1999 and another on the Aqua spacecraft launched in May 2002. MODIS has 36 spectral bands with wavelengths covering from visible (VIS) to long-wave infrared (LWIR). Since launch, M0DIS observations and data products have significantly enabled studies of changes in the Earth system of land, oceans, and atmosphere. In order to maintain its on-orbit calibration and data product quality, MODIS was built with a comprehensive set of on-board calibrators. MODIS reflective solar bands (RSB) are calibrated on-orbit by a system that consists of a solar diffuser (SD) and a solar diffuser stability monitor(SDSM) on a regular basis. Its thermal emissive bands (TEB) calibration is executed on a scan-by-scan basis using an on-board blackbody (BB). The MODIS Characterization Support Team (MCST) at NASA/GSFC has been responsible for supporting sensor calibration and characterization tasks from pre-launch to post launch. In this paper,we describe current MCST efforts and progress made to examine sensor stability and intercalibration consistency using observations over Dome Concordia, Antarctica. Results show that this site can provide useful calibration reference for Earth-observing sensors

    Overview of NASA Earth Observing Systems Terra and Aqua Moderate Resolution Imaging Spectroradiometer Instrument Calibration Algorithms and On-Orbit Performance

    Get PDF
    Since launch, the Terra and Aqua moderate resolution imaging spectroradiometer (MODIS) instruments have successfully operated on-orbit for more than 9 and 6.5 years, respectively. Iv1ODIS, a key instrument for the NASA's Earth Observing System (EOS) missions, was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage earth-observing sensors. In addition to frequent global coverage, MODIS observations are made in 36 spectral bands, covering both solar reflective and thermal emissive spectral regions. Nearly 40 data products are routinely generated from MODIS' observations and publicly distributed for a broad range of applications. Both instruments have produced an unprecedented amount of data in support of the science community. As a general reference for understanding sensor operation and calibration, and thus science data quality, we ;provide an overview of the MODIS instruments and their pre-launch calibration and characterization, and describe their on-orbit calibration algorithms and performance. On-orbit results from both Terra and Aqua MODIS radiometric, spectral, and "spatial calibration are discussed. Currently, both instruments, including their on-board calibration devices, are healthy and are expected to continue operation for several }rears to come

    MODIS On-Board Blackbody Function and Performance

    Get PDF
    Two MODIS instruments are currently in orbit, making continuous global observations in visible to long-wave infrared wavelengths. Compared to heritage sensors, MODIS was built with an advanced set of on-board calibrators, providing sensor radiometric, spectral, and spatial calibration and characterization during on-orbit operation. For the thermal emissive bands (TEB) with wavelengths from 3.7 m to 14.4 m, a v-grooved blackbody (BB) is used as the primary calibration source. The BB temperature is accurately measured each scan (1.47s) using a set of 12 temperature sensors traceable to NIST temperature standards. The onboard BB is nominally operated at a fixed temperature, 290K for Terra MODIS and 285K for Aqua MODIS, to compute the TEB linear calibration coefficients. Periodically, its temperature is varied from 270K (instrument ambient) to 315K in order to evaluate and update the nonlinear calibration coefficients. This paper describes MODIS on-board BB functions with emphasis on on-orbit operation and performance. It examines the BB temperature uncertainties under different operational conditions and their impact on TEB calibration and data product quality. The temperature uniformity of the BB is also evaluated using TEB detector responses at different operating temperatures. On-orbit results demonstrate excellent short-term and long-term stability for both the Terra and Aqua MODIS on-board BB. The on-orbit BB temperature uncertainty is estimated to be 10mK for Terra MODIS at 290K and 5mK for Aqua MODIS at 285K, thus meeting the TEB design specifications. In addition, there has been no measurable BB temperature drift over the entire mission of both Terra and Aqua MODIS

    Summary of Terra and Aqua MODIS Long-Term Performance

    Get PDF
    Since launch in December 1999, the MODIS ProtoFlight Model (PFM) onboard the Terra spacecraft has successfully operated for more than 11 years. Its Flight Model (FM) onboard the Aqua spacecraft, launched in May 2002, has also successfully operated for over 9 years. MODIS observations are made in 36 spectral bands at three nadir spatial resolutions and are calibrated and characterized regularly by a set of on-board calibrators (OBC). Nearly 40 science products, supporting a variety of land, ocean, and atmospheric applications, are continuously derived from the calibrated reflectances and radiances of each MODIS instrument and widely distributed to the world-wide user community. Following an overview of MODIS instrument operation and calibration activities, this paper provides a summary of both Terra and Aqua MODIS long-term performance. Special considerations that are critical to maintaining MODIS data quality and beneficial for future missions are also discussed

    Aqua MODIS Thermal Emissive Band On-Orbit Calibration, Characterization, and Performance

    Get PDF
    The NASA's Earth Observing System Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has continued to operate with satisfactory performance since its launch in May 2002, exceeding its nominal six-year design lifetime. Its continuous Earth observations have been used to generate many science data products for studies of the Earth's, system. MODIS has 36 spectral bands; 20 reflective solar bands and 16 thermal emissive bands (TEBs). All TEB observations are made at 1-km nadir spatial resolution with spectral wavelengths from 3.7 to 14.4 pm. Primary applications of MODIS TEB 'include surface, cloud, and atmospheric temperatures, water vapor, and cloud top altitude. MODIS TEB on-orbit calibration uses a quadratic algorithm with its calibration coefficients derived using an onboard blackbody (BB). This paper will present Aqua MODIS TEB on-orbit calibration, characterization, and performance over its six-year mission. Examples of instrument thermal behavior, BB temperature stability, detector short-term stability, and changes in long-term response (or system gain) will be presented. Comparisons will also be made with Terra MODIS, launched in December 1999. On-orbit results show that Aqua MODIS and its focal plane temperatures have behaved normally. BB temperature has remained extremely stable with typical scan -to-scan variations of less than +/-0.15 mK. Most TEB detectors continue to exceed their specified signal-to-noise ratio requirements, exhibiting excellent short-term stability and calibration accuracy. Excluding a few noisy detectors, either identified prelaunch or occurring postlaunch, on-orbit changes in TEB responses have been less than 0.5% on an annual basis. By comparison; the overall Aqua TEB performance has been better than that of Terra MODIS

    Directional Reflectance Studies in Support of the Radiometric Calibration Test Site (RadCaTS) at Railroad Valley

    Get PDF
    The Radiometric Calibration Test Site (RadCaTS) is a suite of commercial and custom instruments used to make measurements of the surface reflectance and atmosphere throughout the day at Railroad Valley, Nevada. It was developed in response to the need for daily radiometric calibration data for the vast array of Earth-observing sensors on orbit, which is continuously increasing as more nations and private companies launch individual environmental satellites as well as large constellations. The current suite of instruments at RadCaTS includes five ground-viewing radiometers (GVRs), four of which view the surface in a nadir-viewing configuration. Many sensors such as those on Landsat-7 and Landsat-8 view Railroad Valley within 3 of nadir, while others such as those on Sentinel-2A and -2B, RapidEye, Aqua, Suomi NPP, and Terra can view Railroad Valley at off-nadir angles. Past efforts have shown that the surface bidirectional reflectance distribution function (BRDF) has minimal impact on vicarious calibration uncertainties for views <10, but the desire to use larger view angles has prompted the effort to develop a BRDF correction for data from RadCaTS. The current work investigates the application of Railroad Valley BRDF data derived from a BRF camera developed at the University of Arizona in the 1990s (but is no longer in use) to the current RadCaTS surface reflectance measurements. Also investigated are early results from directional reflectance studies using a mobile spectro-goniometer system during a round-robin field campaign in 2018. This work describes the preliminary results, the effects on current measurements, and the approach for future measurements

    Ultra-Portable Field Transfer Radiometer for Vicarious Calibration of Earth Imaging Sensors

    Get PDF
    A small portable transfer radiometer has been developed as part of an effort to ensure the quality of upwelling radiance from test sites used for vicarious calibration in the solar reflective. The test sites are used to predict top-of-atmosphere reflectance relying on ground-based measurements of the atmosphere and surface. The portable transfer radiometer is designed for one-person operation for on-site field calibration of instrumentation used to determine ground-leaving radiance. The current work describes the detector-and source-based radiometric calibration of the transfer radiometer highlighting the expected accuracy and SI-traceability. The results indicate differences between the detector-based and source-based results greater than the combined uncertainties of the approaches. Results from recent field deployments of the transfer radiometer using a solar radiation based calibration agree with the source-based laboratory calibration within the combined uncertainties of the methods. The detector-based results show a significant difference to the solar-based calibration. The source-based calibration is used as the basis for a radiance-based calibration of the Landsat-8 Operational Land Imager that agrees with the OLI calibration to within the uncertainties of the methods

    Landsat 9 TIRS-2 Performance Results Based on Subsystem-Level Testing

    Get PDF
    Landsat 9 is the next in the series of Landsat satellites and has a complement of two pushbroom imagers: Operational Land Imager-2 (OLI-2) that samples the solar reflective spectrum with nine channels and Thermal Infrared Sensor-2 (TIRS-2) samples the thermal infrared spectrum with two channels. The first builds of these sensors, OLI and TIRS, were launched on Landsat 8 in 2013 and Landsat 9 is expected to launch in December 2020. TIRS-2 is designed and built to continue the Landsat data record and satisfy the needs of the remote sensing community. There are two sets of requirements considered for planning the component, subsystem and instrument level tests for TIRS-2: performance requirements and Special Calibration Test Requirements (SCTR). The performance requirements specify key spectral, spatial, radiometric, and operational parameters of TIRS-2 while the SCTRs specify parameters of how the instrument is tested. Several requirements can only be verified at the instrument level, but many performance metrics can be assessed earlier in prelaunch testing at the subsystem level. A test program called TIRS Imaging Performance and Cryoshell Evaluation (TIPCE) was developed to characterize TIRS-2 spectral, spatial, and scattered-light rejection performance at the telescope and detector subsystem level. There were three thermal vacuum campaigns in TIPCE that occurred from November 2017 to March 2018. This work shows results of TIPCE data analysis which provide confidence that key requirements will be met at instrument level with a few minor waivers. A full complement of performance testing will be done at the TIRS-2 instrument level for final verification in late 2018 through Spring 2019

    Absolute Radiometric Calibration of an Imaging Spectroradiometer Using a Laboratory Detector-Based Approach

    No full text
    The HyperSpectral Imager for Climate Science (HySICS) is the core instrument of the Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission and is currently scheduled to be launched to the International Space Station (ISS) in 2023. HySICS is an Offner&ndash;Chrisp imaging spectrometer designed to meet an unprecedented radiometric uncertainty requirement of 0.3% (k = 1) over its entire spectral range of 350&ndash;2300 nm. The approach represents the need for significant improvement over the Radiometric Calibration (RadCal) of existing space-borne spectrometers. One strategy to demonstrate that HySICS achieves this level of accuracy is through an Independent Calibration (IndCal) effort that can provide an alternative referencing RadCal, which follows a traceability chain independent of the operational RadCal of ratioing approach. The IndCal relies on a pre-launch detector-based absolute RadCal of HySICS, using a tunable laser system as source, and the system planned for the HySICS absolute RadCal is the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR was developed at NASA&rsquo;s Goddard Space Flight Center and has been used to calibrate multiple operational remote sensing instruments, as well as the SOlar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS), a calibration demonstration system developed for the CLARREO mission. In this work, the data of SOLARIS GLAMR RadCal conducted in 2019 are processed to derive the Absolute Spectral Response (ASR) functions and other key characterization parameters of SOLARIS detectors. The results are further analyzed with the goals to plan the HySICS GLAMR RadCal, in particular to optimize its configuration, to demonstrate the traceability route to the NIST standard, and to develop the error budget of the calibration approach. The SOLARIS calibration is also compared with other source- and detector-based calibrations to validate the absolute radiometric accuracy achieved

    Band-Averaged Response Sensitivity Study of an Imaging Spectrometer for the CLARREO Pathfinder Mission

    No full text
    Prelaunch absolute, SI-traceable radiometric calibration of satellite-based sensors is key to ensuring the utility of imaging spectrometer-based data products. The development of detector-based calibration techniques leads to the feasibility of meeting the 0.3% uncertainty level needed to provide climate quality data sets. Detector-based calibration is a method in which a well-understood and stable transfer radiometer is calibrated in a standards laboratory to SI-traceable standards, and transported to a facility calibrating a sensor of interest. The transfer radiometer provides the calibration of the source used in the radiometric calibration. A detector-based calibration approach is part of the prelaunch calibration of the CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) sensor with the Goddard Laser for Absolute Measurement of Radiance (GLAMR) system. The SI-traceability of GLAMR is through the electric watt as part of the absolute radiometric calibration of the detectors at the National Institute of Standards and Technology using the Primary Optical Watt Radiometer. The current work uses GLAMR data collected with a visible and near-infrared imaging spectrometer calibration demonstration system to develop a source/sensor modeled calibration data set as part of a sensitivity study to evaluate uncertainties from the spectral sampling and processing methods that accompany the GLAMR calibration process. The spectral &ldquo;supersets&rdquo; include realistic instrumental features as well as effects from the GLAMR source. The methods needed to ensure that spurious sensor and GLAMR data are excluded are described. Results are given from the sensitivity study related to GLAMR spectral sampling and signal-to-noise ratio (SNR) effects, sensor integration time, and frame averaging of the imaging spectrometer data. The study shows that the 6 nm bandwidth sensor simulation requires a 1 nm spectral sampling of the GLAMR source with a radiance level that provides an in-band peak SNR &gt; 200 to ensure that climate quality accuracies can be achieved. The results are also used to refine the test plan for the independent calibration for the CLARREO Pathfinder sensor calibration to optimize test time while meeting the required accuracy levels